Construction in Burundi : an expert warns of collapse risks due to non-compliance with standards
SOS Médias Burundi
Bujumbura, June 13, 2026 – Failure to comply with building construction standards, particularly for multi-story buildings, could expose Burundi to preventable disasters. This is the warning issued by Burundian building construction expert Libère Nitunga at a press conference held Tuesday, June 10, in Bujumbura, Burundi’s commercial capital and home to United Nations agencies and the central government. He denounced the lack of systematic testing of the strength of materials used on many construction sites.
The problem doesn’t primarily stem with the soil
Contrary to some preconceived notions, Libère Nitunga believes that soil characteristics in Burundi are not the main obstacle to construction. According to him, the country generally has suitable land for construction.
He specifies that when geotechnical studies are properly conducted and interpreted according to technical standards, the risks associated with the land remain limited and manageable.
Concrete strength, the main weakness of buildings
For this expert, the real problem lies in the failure to comply with technical standards related to construction materials, particularly concrete.
He points out that internationally, the minimum compressive strength of concrete used in buildings is set at 25 megapascals (MPa).
However, he regrets that in Burundi, this requirement is rarely checked on construction sites.
“The major problem is that we don’t verify whether this strength is actually achieved,” he stated.
According to him, in many public and private projects, including within certain institutions, concrete strength tests are almost never carried out, even though equipment exists to measure the strength of structures already built.
A concerning case study
To illustrate his point, Libère Nitunga cites the case of a property owner who asked him to test the concrete strength on a construction site.
The tests revealed values of 17, 15, and 18 MPa, well below the recommended minimum threshold of 25 MPa.
According to the expert, such a situation exposes the buildings in question to a high risk of structural failure, potentially leading to collapse.
Increased risks with the development of multi-story buildings
Libère Nitunga believes that Burundi remains relatively unaffected, as the majority of buildings are still simple dwellings.
However, he warns against the gradual increase in multi-story buildings without strengthened technical and regulatory controls.
He also emphasizes that Burundi is located in a seismic zone, which requires greater rigor in the design, dimensioning, and monitoring of structures.
According to the expert, strict adherence to building standards and widespread technical inspections are essential measures to prevent potential human and material disasters.
You might also like
Rumonge : power outages and suspicions of corruption at Regideso
SOS Médias Burundi Rumonge, September 14, 2025 – In Rumonge, the power has gone out. In this port city located in southwestern Burundi, residents have been experiencing long power outages
Bubanza : kiongozi wa gereza kukamatwa na kupelekwa jela baada ya mfungwa kutoroka
Kiongozi wa gereza la Bubanza (magharibi mwa Burundi) Émile Nduwayo alisimamishwa jumatatu baada ya kuripoti mbele ya korti ya rufaa ya Bujumbura ( jiji la kibiashara). Faili hiyo ni baada
Switzerland : organizations and experts raise concerns about returns to Burundi and call for a reassessment of asylum practices
Geneva, May 27, 2026 — Civil society organizations, supported by legal experts and human rights specialists, held a press conference on Wednesday to denounce Switzerland’s continued forced returns of Burundian